Characteristics
Construction
Type :
single core cable
Core :
extra flexible tin-plated copper - class 6 as per IEC 60228
Insulation :
silicone rubber with high mechanical properties - type EI 111 as per EN 50382-1
Reinforcing braid :
synthetic reinforcing braid
Sheath :
silicone rubber with high mechanical properties - type EI 111 as per EN 50382-1
Production
Standard :
50 to 185 mm²
Options :
please consult our data sheet FT 5309
Application
Rolling stock :
high temperature power cables with special fire performance for traction and power circuits, with synthetic reinforcing braid within the insulation and extra flexible class 6 tin-plated copper core
Approvals - Standards
Rolling stock :
EN 45545-2, NFPA 130, EN 50382-1, EN 50382-2
Flame retardant, test on bunched cables :
IEC 60332-3-24 / EN 60332-3-24
Flame retardant :
IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free :
IEC 60754-1 / EN 60754-1
Low toxicity :
IEC 60754-2 / EN 60754-2
Low smoke :
IEC 61034-2 / EN 61034-2
General characteristics
Chemical behaviour :
very good resistance to acide, base and mineral oil
Mechanical behaviour :
excellent cut-through resistance and excellent abrasion resistance
Bending radius :
minimal 3 x D as per EN 50355
Motion :
very good resistance to alternate bending
Thermal characteristics
Continuous operating temperature :
-40°C to +120°C
Electrical characteristics
OperatingVoltage :
3.6 / 6 kV
Test voltage :
11 kV A.C.