Characteristics
Construction
Type :
shielded multicore cable
Core :
flexible tin-plated copper - class 5 as per IEC 60228
Insulation :
isovinyl
Shielding :
tin-plated copper braid
Other :
capillary tube (optional)
Sheath :
Profiprene
Colour of outer cable sheath :
blue RAL 5012 or black
Production
Standard :
2x0.22 / 3x0.22 / 2x0.25 / 3x0.25 /4x0.34 / 2x0.5 / 4x0.5
Options :
please consult our data sheet FT 2013
Application
General use :
this cable is especially designed for the power supply of submerged measuring devices (level sensors, piezometric probes, piezoresistive sensors, flow sensors, water quality analysers, etc)
Approvals - Standards
Flame retardant :
IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Bureau VERITAS :
AD8 as per NF C 32-102-16 A-B
General characteristics
Operating environment :
protection from electromagnetic interference
Thermal characteristics
Continuous operating temperature :
-40°C to +70°C (outdoor fixed installation), -25°C to +70°C (outdoor flexible installation), +50°C (underwater fixed installation: )
Electrical characteristics
OperatingVoltage :
300 / 300V
Test voltage :
2000 V